MyGen General FAQ’s
Where do I find good sources about solar?
The Solar Energy Industries Association (SEIA) (http://www.seia.org/) is an excellent source since 1974 to learn about solar energy, its history, industry data, resources and the case for solar. To familiarize yourself with the types of solar energy systems available for residential use, check out the Consumer Guide to Energy and Efficiency and Renewable Energy produced by the U.S. Department of Energy's Energy Efficiency and Renewable Energy Office (http://www.energysavers.gov/)
How does a MyGenTM system work?
The solar cells in the modules convert the sun’s energy into a DC electrical current. This DC current flows into an inverter which changes the DC electricity to AC electricity in order to run household appliances. The AC electricity flows into your electrical service panel to supply power to your home. If your MyGenTM system produces more electricity than you use, the excess electricity is re-routed to your utility line and, in states with net metering laws, is sold to the utility. The utility provides power at night and during the day when your electrical demand exceeds what your solar system produces. During a power outage, your solar system automatically shuts down unless the system includes battery backup.
Will my MyGenTM system work at night and on cloudy days?
Your MyGenTM system will not work at night because solar modules need sunlight to produce power. Solar modules will still produce power on a cloudy day although they will probably only produce about half as much as under full sun.
How do I know if my home is suitable for a MyGenTM system?
Solar electric systems are a viable power solution for most homes. MyGenTM systems are engineered for roof installations in almost any location of the United States where direct sunlight is available. You'll need an unobstructed area of about 115 square feet for an Economy system, and up to 400 square feet for a Mega system. The site must be free from shading. If any portion of the solar panel is shaded, the entire module power output is lowered. A south-facing roof area is ideal, but a west or east facing roof can still produce approximately 90 percent of the power of a south-facing roof.
Can I install the MyGenTM system myself?
No. MyGenTM
systems must be installed by a qualified electrical contractor or
solar installer.
I'm planning on building a new house, when is the best time to
install a MyGenTM system on my roof?
Before laying the roof,
you can install flashable mounting brackets that provide the highest
level of protection from leakage.
What MyGenTM system do I need to produce enough electricity to
run my house?
The solar system size depends on your average
electrical usage, climate, roof angle and many other factors. We
recommend using the 5 step MyGen sizing system to more accurately
determine your electrical needs and the size of your solar system.
Do I need a building permit?
In most areas a permit is
required. Your qualified solar installer will know how to obtain the
necessary permits from your local government.
Do I need approval from my homeowners’ association?
If
you belong to a homeowners’ association, consult your covenants for
details. Many states prohibit homeowners’ associations from
restricting solar devices.
Can Restrictive Covenants/HOA Rules stop me from putting a PV
system on my roof?
Across the country, local zoning laws and
homeowners' associations (HOA) govern the approved uses of a
property. While these rules are often created to ensure uniformity
or uphold a community's aesthetic standard, they may unwittingly
prohibit the installation of solar panels, solar water heaters or
solar heating and cooling technologies. The tide is shifting and
zoning laws are now being used to protect a homeowner's right to
solar access from California to Maryland. SEIA aims to eliminate
zoning laws and HOA rules prohibiting the installation of solar
technologies nationwide. Please see the following related
legislation:
- H.R. 2848 Solar Opportunity and Local Access Rights (SOLAR) Act
- S. 1016 Solar Opportunity and Local Access Rights (SOLAR) Act
Do I need permission from the local utility to connect my
MyGenTM system to the grid?
The local utility has rules and
procedures that must be followed to connect any generator to the
grid safely and legally. Your solar dealer will help you with the
documentation and procedures.
MyGenTM Consumer / Economic FAQ’s
What are the economic benefits for purchasing a MyGenTM system?
1. Save on electricity costs
You can cut or virtually
eliminate your electric bill. With the excess solar power, you can
actually run your electric meter backwards and save!
2. Increase the value of your home
If you’re concerned
that you won’t be in your home long enough to enjoy all the benefits
of the solar system or long enough for the system to pay off, you
should note that you could gain from increased home value as soon as
your system is in. The Appraisal Institute has published articles
showing a $10 to $20 increase in home value for every $1 in reduced
utility costs.
Systems can pay for themselves and provide attractive returns with energy and tax savings
With system financing, up front costs are minimized or eliminated and, frequently, the monthly loan payments are less than your energy and tax savings. The best part is when the loan is paid you continue to enjoy free electricity.
3. Significant state rebates and federal tax credits
Take advantage of various state/local incentives and Federal tax
credits to help pay for your system - frequently 1/3 of your system
cost or more.
4. Gain energy independence and freedom from increasing
electricity rates
Rates have gone up an average of 5.5%
annually over the past 20 years and have gone up
15-20% for many utilities in the past couple of years. With solar you are insulated from expected rate increases.
5. Achieve environmental benefits for purchasing a MyGenTM
system
Obtain energy from a clean, non-polluting, renewable,
dependable source. A typical 5 KW system eliminates more than 6 tons
of CO2 emissions annual. This is the same as planting more than 2.5
acres of trees or cutting your weekly gas consumption by 25 gallons.
Feel good about doing your part to save the planet and be a role
model for your community.
How do the changes to the Investment Tax Credit (ITC) for residential solar projects affect the MyGenTM system?
The following information is intended as general guidelines and not authoritative advice. Consult a tax professional for advice on how the ITC applies to specific situations.
1. When will the new ITC be in effect?
The new ITC will
apply to projects placed into service between January 1, 2009 and
December 31, 2016. The new rules for the ITC will not be
retroactive, so the restrictions on residential installations will
remain in effect through 2008.
2. How did the residential ITC change?
Homeowners will
be able to claim the full 30 percent of the cost of a solar
installation as a federal tax credit; the $2,000-cap will no longer
apply.
3. What happens if a homeowner can’t use the full credit in
the year of installation?
Any unused portion of the
residential ITC can be carried into future years.
4. How does the alternative minimum tax (AMT) affect the ITC?
Tax payers who claim the ITC should no longer be penalized by the
AMT calculations, so AMT filers should be able to claim the full
ITC.
5. Are there size limits on residential projects eligible for
the ITC?
No, projects of any size or cost are eligible.
6. Is the funding for the ITC limited?
No, there are
no limits on the number of taxpayers that can claim the ITC.
7. Can members of a homeowners association (HOA) claim the ITC
for an HOA-owned system?
Yes, members of the HOA are able to
claim the residential ITC in proportion to their share of the HOA’s
expenses; typically a homeowner’s monthly HOA payment should be
directly related to their share of the HOA’s expenses.
MyGenTM Installer FAQ’s
INVERTER
When mounting the inverter, where can I locate the inverter?
The inverter is meant to located either inside a garage or outside
exposed to the elements Do not mount the inverter in a southern
exposed location.
Why is there no neutral, other inverters require a neutral?
A neutral is not required per the revise UL1741 specification. A
neutral measurement was required which PV Powered developed an
alternative measuring technique without the need to pull a separate
Neutral wire. The NEC 2008 Section 690.62 describes the ampacity of
a Neutral Conductor.
690.62 is a conditional statement dictating the size of the wire IF a neutral is used. PV Powered inverters do not require a neutral wire.
Where can I find the dimensions of the PV Powered Inverters?
The data sheets contain detailed physical dimensions for the
Inverter enclosure and knockout locations.
Can the PV Powered inverter be combined with a generator?
No, PV Powered manufactures Grid Tied Inverters only. It is not
recommend nor support the use of our inverters in applications
beyond Grid Tied.
Can the PV Powered Inverter be used for Multiple Pitch and or
Multiple Orientation applications?
The general rule of thumb
for roof pitches and orientation angles are no more than 10%
variance. PV Powered inverters are designed around a single MPPT
(maximum peak power tracking) principle. Greater flexibility is
possible, contact PV Powered for application assistance and
assessment of design impact.
The inverter is reading Ground Fault Code: 0400 0000. What
does this mean?
Check to make sure the proper ground bond
jumper has been installed. If no jumper is installed a Ground Fault
error will be present. If the installation has the proper jumper
installed follow the Installation and Operation Manual for the steps
required to determine if a ground fault is present.
RACKING
What attaches the rack to the roof?
L Feet mounted
through the decking to the roof’s rafters.
How do the rails attach to the roof?
The rails mount to
the L Feet.
How do the PV panels attach to the rack?
End clamps and
mid clamps mount over the frame of the panels via a t-bolt placed in
to the top channel of the rail.
How many PV panels can one kit mount?
One kit will
mount 4 Kyocera KD1 80 series PV modules.
Where do the grounding lugs mount?
On the side of the
rail. One per rail and one on each side of a splice bar if the
splice bar is used.
What attaches to the grounding lugs?
Copper wire.
How do I attach to a standing seam roof?
Use the
optional 3/8” S5! clamps.
Why is a 6” stand off used with a Spanish tile roof?
The stand off sets the height of the rack 6” above the Spanish
tiles.
What is a “flashing” and when would I need it?
A
flashing seals an area on the roof where a stand off has been used
to lift the rack higher above the plane of the roof.
How can you minimize the chances of causing a leak when
mounting an L Foot?
Use a stand off and flashing. Other
options are available.
How do I connect rails together to make a longer span?
Use the Splice bars included with the MyGenTM kit.
An installer wants to mount 12 PV panels to a roof. How many
MyGenTM kits will I need?
Three kits as each MyGenTM kit can
rack up to four Kyocera KD series modules.
How do I add tilt to a PV array?
Use the optional low
profile tilt legs, (qty 3 per kit), attached to a stand off to add
an angled tilt to the PV array.